1、 The positive and negative pole suction plates of the iron core winding machine have not yet reached the supply guide plate before releasing the pieces.
Reason: ① Vacuum damage, incorrect insertion of trachea (front, back or left, right); ② Polar suction confirms poor contact of the sensor.
Solution: ① Replace the trachea; ② Use a multimeter to check if the signal wire is broken and if the sensor is damaged → replace the sensor.
2、 Iron core winding machine malfunction: Automatic mode, pressing the start button is ineffective.
Reason: ① The automatic/manual conversion button or start button is broken; ② The length parameter of the diaphragm is not set.
Solution: ① Replace the switch button; ② Set the parameters.
3、 Iron core winding machine malfunction: positive CV motor does not rotate.
Reason: ① The jog parameter setting is too small; ② Driver parameters not set properly or in alarm state; ③ The motor power cord is not properly connected.
Solution: ① Increase the parameters; ② Set the parameters or shut down and restart → replace the drive; ③ Connect the power cord properly.
4、 Iron core winding machine malfunction: The positive and negative poles RB do not rise after the suction plate descends.
Reason: Pole suction confirms that the sensor has input but no output.
Solution: Use a multimeter to check if the output line is conductive → replace the sensor.
5、 Iron core winding machine malfunction: Negative CV motor overheating alarm.
Reason: ① The setting current parameters of the thermal relay are not set properly or the thermal relay is damaged; ② The bearings or coils on the internal gears of the CV motor are damaged and overloaded.
Solution: ① Set the current setting parameters or replace the thermal relay; ② Replace the motor.
6、 Iron core winding machine malfunction: abnormal diaphragm unwinding motor.
Reason: ① Driver abnormal alarm; ② The power cord is disconnected.
Solution: ① Shut down and restart; ② Connect the power cord properly.
7、 Iron core winding machine malfunction: The speed of the diaphragm unwinding motor is too fast and cannot be adjusted slowly.
Reason: ① The potentiometer is broken; ② The speed control circuit board is damaged.
Solution: ① Use a multimeter to check if the potential is damaged first → Replace the potentiometer ② Replace the circuit board.
8、 Iron core winding machine malfunction: The tension claw has reached the lower limit, and the sensor has sensed it but cannot reset or disconnect.
Reason: ① Tension claw linkage confirmation sensor has input but no output; ② The sensor signal line is connected in reverse between normally open and normally closed.
Solution: ① First use a multimeter to detect a broken signal line → replace the sensor; ② Swap the signal line.
9、 Iron core winding machine malfunction: The winding needle motor does not rotate.
Reason: ① Motor driver power switch tripped; ② The setting of the tension claw variable speed parameter is too small; ③ The tension claw retreat position parameter is set too high; ④ Driver damage; ⑤ The motor power cord has come loose.
Solution: ① Close the power switch; ② Adjust parameters; ③ Adjust parameters; ④ Replace the drive; ⑤ Connect the power cord properly.
10、 Iron core winding machine malfunction: Negative CV motor does not rotate.
Reason: ① Fiber optic induction is not set properly and has been connected; ② The main contact of the thermal relay is damaged; ③ The starting capacitor is damaged.
Solution: ① Set the fiber parameters properly; ② Replace the thermal relay; ③ Replace the capacitor.
11、 Iron core winding machine malfunction: The product discharge motor does not rotate.
Reason: ① Incorrect connection or detachment of motor power cord; ② The motor is stuck and unable to rotate ③ The internal gear bearings of the motor are damaged.